首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   3篇
  免费   0篇
水产渔业   2篇
畜牧兽医   1篇
  2013年   1篇
  2007年   1篇
  1979年   1篇
排序方式: 共有3条查询结果,搜索用时 46 毫秒
1
1.
Four selectively bred strains of Nile tilapia (Oreochromis niloticus) were evaluated for production in brackish water ponds in Indonesia. Survival to 124 days was relatively low for all four strains (39%–48%), and growth during the later stages of the trial was poor (SGR < 1.5 %/day) due to water quality deterioration in the pond. Although the ‘Red’ tilapia strain demonstrated the best production parameters, red-colored tilapia bring lower prices in both our test markets (South Sulawesi and Aceh provinces). Of the four strains, the genetically enhanced supermale Indonesian tilapia?×?genetic improvement of farmed tilapia (GESIT×GIFT) cross provided the best economic return.  相似文献   
2.
3.
Drop-fill water management schemes for aquacultural ponds reduce both groundwater use and effluent release. A drop-fill scheme assumes that pond water level will be allowed to decrease to the “drop” depth before makeup water is used to return it to the “fill” depth, which is typically some fraction (e.g., 1/2) of the drop depth. This paper compares predicted performance of drop-fill schemes at five sites in the Southeast U.S. (Thompsons, TX, Stuttgart, AR, Stoneville, MS, Clemson, SC, and Fairhope, AL). The locations were chosen to assess the effect of the east–west precipitation gradient and the south–north change from maritime to continental characteristics on the drop-fill approach in this region.

Performance of the drop-fill schemes was based on calculated daily water balances for ponds using 40-year (1961–2000) precipitation (P) and evaporation (E) records at the sites. Pond evaporation is assumed to be 0.8 × pan evaporation. Since performance differences based on regional P minus E (P−E) records was the subject of this work, ponds were assumed identical in other respects (i.e., all ponds were assumed to be levee-type and to have zero infiltration).

Simulated drop-fill schemes tested included (in cm): 0/0, 5/2.5, 10/5, 15/7.5, 20/10, 25/12.5, 30/15, 45/22.5, 60/30, 90/45, and 120/60. Each scheme was simulated using daily time steps for 40 years at each site. Results suggested that rigorous adherence to even a modest drop-fill scheme results in substantial reductions in both groundwater use and effluent release. It also appears that P−E conditions at all sites allow implementation of more aggressive drop-fill schemes in properly designed ponds that will require no supplemental groundwater for most years. This was also true with respect to effluent release at three of five sites. At two sites, precipitation was sufficiently large that zero effluent years were either not predicted (Fairhope) or relatively uncommon (Clemson) for any drop-fill scheme.  相似文献   

1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号